Micro i.s. 5100

Ürün Talep Formu İçin Tıklayınız

Designed to meet the demands of the most dangerous environments, Micro i.s. delivers ultra-sensitive percentage measurements for oxygen, carbon monoxide and carbon dioxide. A tough, life-proof design and feature-rich performance ensures maximum operational flexibility.

Micro i.s. is Intrinsically safe (i.s.) and is able to analyze both flammable and toxic samples. This intelligent design means that no purge is required prior to device use.

Micro i.s. also provides an intuitive user interface, the ability to store up to 200 measurements and up to 18 hours battery run time.

High performance oxygen, carbon monoxide and carbon dioxide portable gas analysis, designed for use in hazard rated locations including Zone 0/Division 1

Gas: CO2, CO, O2

Measures: %

Application: Process Control and Safety

Sensing Technology: Infrared and Paramagnetic


  • Hazardous area combustion optimization
  • Natural gas processing
  • Refineries – catalytic cracker regeneration
  • HyCO applications
  • Cracker decoke cycle on petrochemical plant
  • Process monitoring
  • Inerting applications


  • Intrinsically safe (i.s) design permits use in any hazard rated location including Zone 0/Div. 1 
  • Gas analysis for O2, CO or CO2
  • Pumped or non-pumped (AFCD) functions
  • IP65 rating

Easy to use

  • Intuitive, engineer-friendly interface and icons
  • Stores up to 200 measurements for subsequent download
  • Ergonomic design with carry strap

Low cost of ownership

  • Uses non-depleting sensor technologies that reduce ongoing maintenance costs
  • Advanced Li-Ion rechargeable batteries as standard (up to 18 hour run time)

Unrivalled Performance

  • Uses industry-leading patented Paramagnetic and IR technologies and algorithms for ultra-sensitive and accurate measurements
  • Manufactured by Servomex - over 60 years’ experience innovating and pioneering gas analysis with thousands of units used in the field every year

Benchmark compliance

  • ATEX: Ex ia (Intrinsically Safe) IIC T4 Ga (-10°C≤Ta≤+50°C) (+14°F≤Ta≤+122°F) 
  • IEC: Ex ia (Intrinsically Safe) IIC T4 Ga (-10°C≤Ta≤+50°C) (+14°F<_Ta≤+122°F) 
  • FM: IS/I/1/ABCD/T4; -10°C≤Ta≤+50°C: IP65 (Division 1) 
  • FM: IS/I/0/AEx ia/IIC/T4; -10°C≤Ta≤50°C: IP65 (Zone 0) 
  • CSA: IS/I/1/ABCD/T4; -10°C≤Ta≤+50°C: IP65 (Division 1) 
  • CSA: IS/I/0/Ex ia/IIC/T4; -10°C≤Ta≤+50°C: IP65 (Zone 0) 


  • 160mm (6.3”) Width x 185mm (7.2”) High x 140mm (7.2”) Deep


  • 1.8kg – 2.3kg (4lbs – 5.1lbs)


  • ATEX: Ex ia (Intrinsically Safe) IIC T4 Ga (-10°C_
  • IEC: Ex ia (Intrinsically Safe) IIC T4 Ga (-10°C_
  • FM: IS/I/1/ABCD/T4; -10°C_
  • FM: IS/I/0/AEx ia/IIC/T4; -10°C_
  • CSA: IS/I/1/ABCD/T4; -10°C_
  • CSA: IS/I/0/Ex ia/IIC/T4; -10°C_
  • CE marked and in compliance with ATEX, EMC and WEE Directives scope UL approved and CE marked 100-240V / 43-70Hz AC power supply